The AutomaSol TDI WEB model is a temperature differential controller ideal for managing heated pool systems.It features differential control linked to a setpoint, activating the circulation pump based on the temperature difference between the collectors and the storage tank. Its compact design, combined with multiple protection functions and a surface-mount installation system, ensures easy installation.

User guide
Solar heating systems

Solar heating systems

Pump activation by temperature differential

Pump activation by temperature differential

Ideal for solar heated pools

Ideal for solar heated pools

Circulation pump management

Circulation pump management

The AutomaSol TDI WEB model is a temperature differential controller ideal for managing heated pool systems.It features differential control linked to a setpoint, activating the circulation pump based on the temperature difference between the collectors and the storage tank. Its compact design, combined with multiple protection functions and a surface-mount installation system, ensures easy installation. The AutomaSol TDI WEB controller also includes a digital display for temperature monitoring and keys for manual or automatic pump control and is compatible with Ageon’s monitoring devices, WebFi and WebFi Pro.

Supply voltage: (85 a 265) Vac;

Maximum power: 5 VA;

Relay outputs:

Resistive load: 15 A / 220 VAC;

Inductive load: 2 HP / 220 VAC or 1 HP / 127 V;

Measurement range: (-20 to +100) °C;

Operating conditions: (0 to 40) °C and (10 to 90) % RH (noncondensing);

Dimensions: (91 x 132 x 41) mm;

Protection Index: NTC Sensor (IP 68);

NTC sensor: Ø6 mm / L=15 mm (sensor); Standard length 1,5 m (wiring).

Solar heating

The AutomaSol TDI WEB is a controller designed for water heating systems in pools or storage tanks, allowing configuration of the circulation pump to ensure efficient temperature control.

Circulation pump activation

In addition to automatic activation based on temperature differential, the pump can be manually activated via the “PUMP” key, with a configurable runtime before returning to automatic mode, ensuring convenient and reliable control.

Surface mounting

To facilitate access to the controller and adapt to different installation environments, the AutomaSol line features a surface-mount design, ensuring simple and versatile installation without the need for panel cutouts.

Compatible with WebFi and FastKey

The AutomaSol TDI WEB model can be monitored remotely with WebFi as well as store and reproduce parameters with FastKey.

Frequently asked questions

The factory-set temperature differential of the AutomaSol TDI WEB is configured for general use in solar heating systems. However, the ideal differential may vary depending on the specific characteristics of each installation. Testing the system or consulting a qualified professional is recommended to determine the most appropriate temperature differential for your application.

Yes, the AutomaSol TDI WEB has an automatic wide-range power supply (85–265 VAC), ensuring compatibility with different mains standards.

  • Monitoring collector and storage tank temperatures;
  • Controlling circulation pumps to maximize thermal efficiency;
  • Configuring alarms to prevent overheating or adverse conditions;
  • Logging operating data for performance analysis.

Errors E1 and E2 are related to the AutomaSol TDI WEB temperature sensors. The controller uses two sensors—one for the collector and one for the storage tank—each associated with a specific error code.

  • E1: Collector sensor error;
  • E2: Storage tank sensor error.

In both cases, check that the cables are properly connected and free of damage. Also ensure that the measured temperature is within the controller’s operating range (-20°C to 105°C).

The AutomaSol TDI WEB is a differential temperature controller developed by Ageon for solar heating systems. It optimizes heat transfer, ensuring high efficiency and energy savings.